Skip to main contentSkip to navigationSkip to contactAccessibility (Alt+A)

Keyboard Shortcuts

  • Alt + A: Open accessibility settings
  • Tab: Navigate to next element
  • Shift + Tab: Navigate to previous element
  • Enter or Space: Activate buttons and links
  • Escape: Close dialogs and menus
  • Arrow keys: Navigate within menus and sliders
  • Home: Go to beginning of list
  • End: Go to end of list
EmersonEIMS — Reliable Power. Without Limits.
HOMEABOUT
CONTACT
Get Quote

B2BEmersonEIMS serves commercial, industrial, healthcare, telecom, hospitality, government & contractor clients.• Engineering-led • SLA-backed • Documented commissioning

Talk to an engineerWhatsApp+254 768 860 665

Services Directory

View all services →

Power & Generators

  • Cummins Generators (3-yr warranty)
  • Generator Repairs & Maintenance
  • ATS / Changeovers
  • Generator Sales
  • Generator Rental
  • Generator Installation
  • Generator Spare Parts
  • Power Interruption Solutions

Renewable & UPS

  • Solar Energy Solutions
  • Commercial / Industrial Solar
  • Solar System Sizing
  • Solar Genius Pro™
  • UPS Systems
  • UPS Lab
  • Solar / UPS Hub
  • Borehole Pumps

Electrical & HVAC

  • Distribution Boards & Panels
  • Motor Rewinding
  • Motors & Drives
  • High-Voltage Systems
  • Diesel Automation
  • Industrial Controls
  • Steel Fabrication
  • AC / HVAC Installation

Specialised & AI Suites

  • Hospital Incinerators
  • Incinerator Construction Guide
  • Building Engineering Suite
  • EIMS PRO Workspace
  • AquaScan Pro™
  • Generator Oracle™
  • Diagnostics Hub
  • Troubleshooting Wizard

Maintenance Hubs

  • Generator Maintenance
  • Solar Maintenance
  • HVAC Maintenance
  • Borehole Maintenance
  • Electrical Maintenance
  • Motors Maintenance
  • Incinerator Maintenance
  • Fabrication & Welding

Resources & Tools

  • Resources & Learning Hub
  • Knowledge Base
  • Technical Bible
  • Power Calculators
  • Fault Code Database
  • Blog & Articles
  • FAQ
  • Emergency Response Guide

Service Areas

  • All Kenya — 47 Counties
  • Nairobi
  • Mombasa
  • Kisumu
  • Nakuru
  • Kiambu
  • All Service Locations
EMERSONEiMS

Engineering-grade reliability for East Africa's critical infrastructure. Power systems built to perform.

  • LinkedIn↗
  • Twitter↗
  • Facebook↗

Company

  • About Us
  • All Services
  • Book a Service
  • Project Gallery
  • Case Studies
  • Industries Served
  • Careers
  • Contact Us

Quick Links

  • Generator Sales
  • Solar Energy
  • Diagnostic Suite
  • Solar / UPS Hub
  • Generator Oracle
  • Knowledge Base
  • FAQ

Contact

  • Nairobi HQEmbakasi, off Airport North Road, Nairobi
    (Near KEMSA Head Office)
  • Department Emails
    • General Inquiriesinfo@emersoneims.com
    • Service Coordinationemersoneimservices@emersoneims.com
    • Generator Deskgenerators@emersoneims.com
    • Solar & UPS Desksolar@emersoneims.com
    • Sally — Direct Accountsally@emersoneims.com
  • Phone
    +254782914717
    +254768860665

© 2026 Emerson EiMS. All rights reserved.

Privacy PolicyTerms of Service
ENGINEERED IN NAIROBI, KENYA
  1. Home
  2. /
  3. Fault Codes
  4. /
  5. PERKINS-115
Perkins

PERKINS-115

Engine Speed Sensor Signal Lost

🚨CRITICAL

The ECM is not receiving a valid signal from the engine speed/position sensor. Without this signal, fuel injection timing cannot be calculated and the engine will not start or will stall. This is a critical fault requiring immediate attention.

🔍 Possible Causes

  • •Speed sensor failure
  • •Wiring damage or disconnection
  • •Sensor gap out of specification
  • •Damaged flywheel ring gear teeth
  • •Corroded sensor connector
  • •ECM speed input circuit failure

🔧 Troubleshooting Steps

  1. 1Check sensor connector for moisture or corrosion
  2. 2Measure sensor resistance - typically 200-1000 ohms
  3. 3Verify sensor gap to flywheel - typically 0.5-1.5mm
  4. 4Inspect flywheel teeth for damage
  5. 5Check wiring continuity from sensor to ECM
  6. 6Use EST to verify signal during cranking

🛠️ Parts You May Need

Speed/Timing SensorSensor Wiring HarnessSensor ConnectorFlywheel Ring GearSensor Mounting Bracket

Need parts? We stock genuine Perkins parts with next-day delivery in Nairobi.Call +254 768 860 665

❓ Frequently Asked Questions

How do I check the Perkins speed sensor gap?

Use a feeler gauge to measure the gap between sensor tip and flywheel teeth. Specification is typically 0.5-1.5mm. Too large a gap causes weak signal; too small risks sensor damage.

What type of sensor does Perkins use for engine speed?

Perkins uses a magnetic pickup sensor (Variable Reluctance) on most engines. Some newer models use Hall Effect sensors. Check your engine manual for specifications.

Need Expert Help?

Our engineers have fixed 1,000+ Perkins generators. Get professional diagnosis now.

WhatsApp EngineerCall +254 768 860 665

Advanced Diagnostics

Use Generator Oracle for AI-powered diagnosis, wiring diagrams, and repair manuals.

Launch Generator Oracle →

Related Fault Codes

SPN-115Engine Speed Sensor - No SignalSPN-190Engine Overspeed WarningDSE-E040Underspeed WarningCOMAP-A015Engine Overspeed Shutdown