Technical Reference
Fault diagnosis and repair guidance for diesel generating sets, inverters, UPS systems and generator controllers. Every guide ranks its causes by likelihood, gives an ordered diagnostic sequence with the reading expected at each step, and states the safety constraints rather than assuming them.
Where a value is specific to your model, the guide says so and tells you what to confirm against the manufacturer's documentation. We would rather send you to the service manual than invent a number.
Diagnosis and repair guidance for diesel generating sets — starting faults, protective shutdowns, output problems, cooling, fuel and control systems. Written for technicians working on real plant, with the safety constraints stated rather than assumed.
Fault diagnosis for off-grid, hybrid and grid-tied inverters, including output-stage, charging and thermal faults. Board-level guidance is published only where it can be given safely and accurately.
Diagnosis for offline, line-interactive and online double-conversion UPS systems, including bypass behaviour, battery autonomy and the generator interaction that causes most critical-power failures.
Component-level diagnosis and board repair for industrial control and power electronics — locating shorted rails, tracing supply chains, and deciding when a board is worth repairing at all. Published only where the method can be given without inventing values: every board-specific voltage, pinout and component value is deferred to the manufacturer reference.
Automatic transfer switch and changeover panel faults — why a switch refuses to transfer, how to separate a control decision from a mechanical failure, and the interlock rules that exist to stop utility and generator being connected together.
Three-phase motor faults — windings, bearings and the supply problems that destroy otherwise healthy machines. Most burnt-out motors were killed by something outside them, so these guides diagnose the installation as well as the machine, and set out honestly when a rewind is worth it and when it is not.
Borehole and water pump faults — level, hydraulics, delivery path and the electrical side down the hole. Most of the diagnosis belongs at the surface, because pulling a pump is expensive and hazardous and is frequently unnecessary once the water level has actually been measured.
Solar array and system faults — yield, strings, shading, soiling and the difference between a real fault and an expectation set against nameplate. Written to establish what output SHOULD be for the conditions first, because without that reference "underperforming" is an opinion rather than a measurement.
Variable-speed drives and industrial power electronics — reading a trip correctly, and separating a genuine drive failure from the load, ramp, cooling or installation defect that caused it. Includes the practices that reliably destroy drives and are still found on live installations.
The disciplines every other guide in the Repair Centre depends on — identifying every source, locking off, proving dead at the point of work, and controlling stored energy. Power equipment routinely has more than one source, and several of them cannot be switched off at all.
Diesel fuel, air and combustion faults — smoke diagnosis, fuel contamination, injection and the loading problems that damage engines without any component failing. Written for Kenyan conditions, where dust loading, altitude derating and long-stored fuel matter more than temperate assumptions allow.
Choosing instruments, using them safely, and knowing where each one misleads. Measurement category is a safety rating rather than an accuracy one, and the two commonest field errors — averaging meters on distorted waveforms, and ghost voltages on high-impedance inputs — both produce confident, entirely believable wrong numbers.
How to read the codes your equipment reports — the structure behind J1939 engine diagnostics, and why a code identifies a measurement rather than a cause. Written to make a code database usable: the aim is a technician who can interpret an unfamiliar code correctly, not one who looks up a number and stops thinking.
Diesel engine mechanical condition — abnormal noise, lubrication and the judgements where continuing to run costs far more than stopping. The urgent decision on this equipment is usually not what the fault is, but whether the engine should be running while you work it out.
Fault interpretation for generator controllers including DSE, ComAp, Woodward, SmartGen, PowerWizard, Datakom, Lovato, Siemens, Enko and Volvo Penta VODIA.
Cummins, Perkins, Caterpillar, Volvo Penta, Deutz, Doosan, FG Wilson, SDMO and other electronic or mechanically governed diesel sets
Cummins, Perkins, Caterpillar, Volvo Penta, Deutz, Doosan, FG Wilson, SDMO and other electronically or mechanically governed diesel sets
All diesel generating sets with oil pressure protection — Cummins, Perkins, Caterpillar, Volvo Penta, Deutz, Doosan, FG Wilson, SDMO and others
Brushless and brushed synchronous alternators fitted to Cummins, Perkins, Caterpillar, FG Wilson, SDMO and other sets. Stamford, Leroy-Somer, Marathon, Mecc Alte and equivalent generator ends.
Brushless and brushed synchronous alternators with electronic AVRs, on mechanically or electronically governed diesel sets
Open and canopied diesel generating sets, single- and three-phase, standby and prime
Brushless self-excited and PMG-excited alternators on diesel generating sets, single- and three-phase
Diesel generating sets with electric starting, single- and three-phase, standby and prime
Online double-conversion UPS systems with static bypass, single- and three-phase, including modular and parallel installations
Control boards, power-supply boards, driver boards and control panels in generators, inverters, UPS systems and industrial plant. Method is general; all board-specific values must come from the manufacturer reference.
Control motherboards in generator controllers, inverter and UPS control sections, drives and industrial control panels. Method is general; every rail voltage must come from the board reference or regulator data.
Contactor-based and motorised automatic transfer switches, single- and three-phase, controlling utility and generator supplies
Diesel generating sets with electric starting, standby and prime, with engine-driven charging alternator and separate mains battery charger
Online double-conversion UPS systems, single- and three-phase, including modular and parallel installations
DeepSea, ComAp, SmartGen, PowerWizard, Woodward, Datakom, Lovato and similar generating-set controllers. Method is general; every code meaning must come from the manual for that exact controller and firmware.
Three-phase squirrel-cage induction motors on direct-on-line, star-delta, soft-start and variable-speed drives
Submersible borehole and well pumps, single- and three-phase, on direct-on-line, soft-start or variable-speed control
Grid-tied, hybrid and off-grid PV systems, roof and ground mounted, single- and three-phase
Variable frequency and variable-speed drives on pumps, fans, compressors and conveyors, single- and three-phase input
Generating sets, UPS systems, inverters, solar installations, drives, motors and control panels
Naturally aspirated and turbocharged diesel generating sets, mechanical and electronically controlled injection
Multimeters, clamp meters, insulation testers, voltage indicators and thermal cameras used on generators, UPS systems, inverters, drives and installations
Generating sets and plant with electronically controlled engines reporting diagnostics over a J1939 CAN link to a controller or display
Diesel engines in generating sets and plant, naturally aspirated and turbocharged
PWM and MPPT charge controllers in off-grid and hybrid systems, lead-acid and lithium banks
Three-phase motors on direct-on-line, star-delta and soft-start control, with thermal or electronic overload protection
Borehole, booster and transfer pumps under pressure-switch, level or variable-speed control
Generating sets with automatic mains-failure controllers including DeepSea, ComAp, SmartGen, PowerWizard, Datakom and Woodward
VRLA and lithium battery strings in single- and three-phase UPS systems, cabinet and rack mounted
Contactor-based and motorised automatic transfer switches on utility and generator supplies, single- and three-phase
Standby and prime generating sets with bulk or day tanks, mechanical and common-rail injection
Low- and high-frequency off-grid inverters, hybrid inverters and inverter-chargers on 12 V, 24 V and 48 V battery systems
Off-grid, hybrid, grid-tied and inverter-charger units, low- and high-frequency, single- and three-phase
Inverter-chargers, hybrid and off-grid inverters charging from utility, generator or solar, with lead-acid or lithium banks
MOSFET output and boost stages in off-grid, hybrid and inverter-charger units. Method is general; every device value must come from the manufacturer data for the specific part.
Discrete IGBTs and IGBT modules in inverters, UPS power stages and variable-speed drives. Method is general; every device parameter must come from the manufacturer data for the specific part.
Grid-tied, hybrid and off-grid solar inverters with MPPT PV inputs, single- and three-phase
Offline, line-interactive and online double-conversion UPS systems, single- and three-phase, with VRLA or lithium battery strings
Offline, line-interactive and online double-conversion UPS systems, single- and three-phase, on mains or generator supply
Looking up a specific controller alarm rather than reading a guide? The Generator Oracle carries the fault-code database with reset pathways.